The INVESTIGATION OF ELECTROMAGNETIC CURRENT TRANSFORMER PERFORMANCE CHARACTERISTICS FOR MEASURING AND CONTROLLING THE REACTIVE POWER DISSIPATION OF A SHORT-CIRCUITED ROTOR SYNCHRONOUS MOTOR
We know that we have been using asynchronous motors, which are widely used in the industry and production of the world and in our country, and despite a number of advantages of this type of motor, there are also enough disadvantages. In order to eliminate these shortcomings, the aim of the article is to reduce the rapid burning of the asynchronous motor by adding an additional sensitive element to the stator slot of the asynchronous motor. and in order to prevent premature failure, the recommended method is effective enough to increase energy consumption and service life.
Ключевые слова:
Magnetic driving force, voltage, current, output voltage, contact, circuit, converter, asymmetryАннотация
We know that we have been using asynchronous motors, which are widely used in the industry and production of the world and in our country, and despite a number of advantages of this type of motor, there are also enough disadvantages. In order to eliminate these shortcomings, the aim of the article is to reduce the rapid burning of the asynchronous motor by adding an additional sensitive element to the stator slot of the asynchronous motor. and in order to prevent premature failure, the recommended method is effective enough to increase energy consumption and service life. It is known that the main reasons for the failure of the motor are the asymmetry of the electrical parameters in the motor, the increase in temperature and the reduction of energy consumption. In order to prevent the negative consequences of the motor, current transformers serve to further increase the efficiency of the device and to detect and protect the motor's bad condition in advance.