UO‘K 677.21 THE EFFECT OF THE ANGLE OF HEAT AGENT SUPPLY TO THE DRYING- CLEANING\ EQUIPMENT ON COTTON QUALITY AND CLEANING EFFICIENCY OF THE EQUIPMENT
DOI:
https://doi.org/10.61151/stjniet.v9i4.596Keywords:
seed cotton, spiked cylinder, small and large trash, moisture, cleaning efficiencyAbstract
In order to effectively dry cotton and clean it from small impurities at the same time, the temperature of the air supplied from the upper side of the cleaner at a deviation angle of 300, 450, 600 degrees to the horizontal axis along the length of the cleaner is from 75 0C to 100 0C, the air consumption is from 8 thousand m3/hour to 10 when it is increased to thousand m3/h, the effect on the change of dirt in cotton and cleaning efficiency was studied.

Downloads
Published
2024-12-27
How to Cite
SALOMOVA, M., Sharipov, X., & Timur , T. (2024). UO‘K 677.21 THE EFFECT OF THE ANGLE OF HEAT AGENT SUPPLY TO THE DRYING- CLEANING\ EQUIPMENT ON COTTON QUALITY AND CLEANING EFFICIENCY OF THE EQUIPMENT . Scientific and Technical Journal of Namangan Institute of Engineering and Technology, 9(4), 28–34. https://doi.org/10.61151/stjniet.v9i4.596